Button image: Home Page Button image: Contact Us
Button image: Wall Ties Button image: Masonry Restraint Button image: Masonry Support Button image: Windposts Button image: Parapet Posts Button image: Lintels Button image: Channels Button image: Fixings Button image: Sockets
Anchors Button Image
Self Drilling/Tapping Screws Button Image
HS Bolts Button Image

 

GA Fixings
Unit 34
Claycliffe Business Park
Cannon Way
Barugh Green
Barnsley
S75 1JU

Tel: 01226 380779
Fax: 01226 385558

Email: info@gafixings.com

M.D. Anchors

 

M.D. Anchors are used for fixing back to concrete, they are quick to install and offer good load performance in both shear and tension.

M.D. Anchors are available in zinc plated and stainless steel versions.

Anchor Size
Length
M6
55
M8
M10 M12 M16 M20
70 100 90 120 100 120 125 175 160 200
Max Fixing Thickness
15/5
25/15
55/45
35/25
65/55
35/15
55/35
45/25
95/75
60/35
100/75
Hole Diameter
6
8
10
12
16
20
Hole Depth
41
51
48
58
60
70
72
92
91
111
100
140
Anchor Depth
35
45
40
50
50
60
60
80
75
95
95
120
Centre Spacing
80
120
100
130
130
175
155
225
200
250
260
340
Edge Distance
60
70
85
90
105
115
125
140
175
185
215
230
S.W.L. Shear
3.1
3.1
5.7
5.7
9.1
9.1
13.2
13.2
24.5
24.5
38.3
38.3
S.W.L. Tension
1.9
2.8
3
4.6
4.5
7.6
6.6
11.4
8.9
13.9
13.4
17.9
Tightening Torque
10
20
45
65
120
180
Anchor Size
Depth
M6 M8 M10 M12 M16 M20
35 45 40 50 50 60 60 80 75 95 95 120
Load Reduction
Factors for
Reduced Anchor
Spacing
1
80
120
100
130
130
175
155
225
200
250
260
340
0.95
72
108
90
117
117
158
140
203
180
225
234
306
0.9
64
96
80
104
104
140
124
180
160
200
208
272
0.85
56
84
70
91
91
723
109
135
120
150
156
204
0.8
48
72
60
78
78
105
93
135
120
150
156
204
0.75
40
60
50
65
65
87
77
113
100
125
130
170
0.7
32
48
40
52
52
70
62
90
80
100
104
136
Load Reduction
Factors for
Reduced Anchor
Spacing
1
60
70
85
90
105
115
125
140
175
185
215
230
0.95
55
64
78
82
97
105
115
127
161
170
198
210
0.9
50
57
72
75
88
95
105
115
148
154
181
190
0.85
45
51
65
67
80
85
95
102
134
139
163
170
0.8
40
44
58
59
71
75
85
90
120
123
146
150
0.75
35
38
51
51
63
64
74
77
106
108
129
130
0.7
30
31
45
44
54
54
64
64
93
92
112
110
Chemical Anchors

Chemical anchor studs are used with both the chemical capsule and chemical injection type fixing. The studs are available in zinc plated, galvanised and grade A2 stainless steel. (A4 available on request).

C.C. Anchors
Chemical capsules consist of a resin mixture and a small internal tube of hardener which when mixed cure to give a high load anchorage point.
Anchor Size
Length
M8
110
M10
130

M12
160

M16
190
M20
260
M24
300
Max Fixing Thickness
18
25
34
45
55
55
Hole Diameter
10
12
14
18
25
28
Hole Depth
80
90
110
125
170
210
Anchor Depth
80
90
110
125
170
210
Centre Spacing
120
140
165
190
260
320
Edge Distance
100
110
135
155
210
260
S.W.L. Shear
4.1
6.6
9.7
19.1
28.8
41.7
S.W.L. Tension
6
9
12
20
30
38
Tightening Torque
10
20
40
95
180
315
C.I. Anchors
Chemical injection mortars are used where close edge and centre distances are required together with high load performance.
Anchor Size
Length
M8
110
M10
130

M12
160

M16
190
M20
260
M24
300
Max Fixing Thickness
18
25
34
45
55
55
Hole Diameter
10
12
14
18
25
28
Hole Depth
80
90
110
125
170
210
Anchor Depth
80
90
110
125
170
210
Centre Spacing
80
90
110
125
170
210
Edge Distance
60
70
85
100
130
160
S.W.L. Shear
3.9
6.3
9.1
16.3
25.5
36.6
S.W.L. Tension
3.4
4.9
6.8
9.8
14.8
26.5
Tightening Torque
7
11
25
50
115
140